Product Details:
Brand | Coatmaster |
Model Name / Number | Coatmaster 3D |
Measurement area | freely scalable |
Pixels per measurement | 382 x 288 |
Measurement time | 0.5s |
Tilt tolerance | +-70 Degree |
Distance tolerance | 10 - 120 cm |
Product Details:
Mobility | Portable |
Brand | CHN Specs |
Warranty | 1 Year |
Wavelength Pitch | 10nm |
Model | CS-580/600/650/660 |
Reflectance Range | 0-200% |
Half Band Width | 5nm |
Product Details:
Brand | Coatmaster |
Model Name / Number | coatmaster Atline |
Usage/Application | Laboratory |
Substrate | Metal, Plastic/Rubber |
Smallest measuring point | 1 mm |
Substrate: Metal |
|
Powder coatings before curing |
10 – 300 um |
Wet coatings before drying |
1 – 300 um |
Cured powder coatings |
1 – 1000 um |
Dried wet coatings |
1 – 1000 um |
Substrate: Plastic/Rubber |
|
Wet coatings before drying |
5 – 150 um |
Dried wet coatings |
5 – 50 um |
Substrate: Wood/MDF |
|
Powder coatings before curing |
10 – 150 um |
Wet coatings before drying |
10 – 250 um |
Measuring time |
from 20 ms |
Distance Tolerance |
5 – 120 cm |
Tilt tolerance |
± 70 |
Measurement on moving and jiggling parts |
yes up to 120 m/min |
Relative standard deviation* |
<1 % |
Smallest measuring point |
1 mm |
Works on all colors (incl. white) |
yes |
Real-time data access via ERP and Internet browser |
yes |
Dimensions HxWxD |
200 x 380 x 510 mm |
Weight |
16 kg |
Product Details:
Usage/Application | Laboratory |
I Deal In | New Only |
Standards | ASTM F2357-04, ASTM F2357-10 & ASTM F3152-16 |
Brand | Norman Tool |
Model | RCA Abrasion Wear Tester |
Product Details:
Brand | Lovibond UK |
Model Name/Number | AF 710-3 |
Power Supply | 230 V / 50-60 Hz or 115 V / 50-60 Hz |
Applicable Standard | AOCS Cc 8d-55 AOCS Cc 13b-45 AOCS Cc 13j-97 |
Color Type | Transparent |
Power Supply | 230 V / 50-60 Hz or 115 V / 50-60 Hz |
Portability | Benchtop |
Touchscreen | No |
Product Details:
Measuring Range | -80 DegreeC to +50 DegreeC |
Model Name/Number | FA 500 |
Operating temperature: | -20 to +50 DegreeC |
Protection class: | IP 65 |
Brand | CS Instruments |
With the FA 500 you make the right choice for highest precision in dew point measurements. Our sensor offers a wide span of measuring ranges perfectly matched to the needs of different compressed air dryers. Rely on us for accurate results in any situation.
Monitoring a compressed air dryer is critical to increase energy efficiency, ensure product quality, prevent machine damage, identify maintenance needs and achieve cost savings. This contributes to the smooth operation of compressed air systems in various industrial applications.
Special features:
• Integrated display
• Threshold value adjustable via keypad, alarm relay (max. 60 VDC, 0.5 A)
• Pressure-tight up to 500 bar (special version)
• Extremely stable in the long term
• Quick adaption time
• 4...20 mA analogue output for dew point
• Diff erent refrigeration and adsorption dryer versions
• NEW: Modbus-RTU interface
• NEW: Higher resolution of sensor signal due to the improved evaluation electronics
• NEW: Sensor diagnosis on site with a portable device or CS Service Software
Readable via Modbus:
- Pressure dew point [°Ctd.]
- Temperature [°C]
- rel. humidity [% RH]
- abs. humidity [g/m³]
- Degree of humidity [g/m³]
- Moisture content V/V [ppmV/V]
- Water vapour particle pressure [hPa]
- Atmospheric dew point [°Ctd.atm]
Product Details:
Brand | Lovibond UK |
Warranty | 1 Year |
Model | Fx |
Wavelength Range | 380 - 780 nm |
Wavelength Accuracy | 0.2 nm |
Languages User Interface | English, German, French, Spanish, Italian, Portuguese, Russian, Japanese, Chinese |
Dimensions | 301 x 152 x 331 mm |
Color Type | Transparent |
Wavelength Range | 380 - 780 nm |
Wavelength Accuracy | 0.2 nm |
Spectral Scope | < 15 nm |
Photometric Range | 0 - 100 % T |
Photometric Linearity | ± 0.01 % T |
Stray Light | < 0.01 % T |
Detector | Spectrometer |
Interfaces | USB RS 232 |
Portability | Benchtop |
Touchscreen | No |
Input Voltage | 110 VAC, 250 VAC, 60 W (24 V) |
Compliance | CE |
Languages User Interface | English, German, French, Spanish, Italian, Portuguese, Russian, Japanese, Chinese |
Dimensions | 301 x 152 x 331 mm |
Product Details:
Brand | Anton Paar Austria |
Usage/Application | Laboratory |
Model Name/Number | DMA 35 |
Power Supply | Three 1.5 V LR06 AA alkaline batteries |
Accuracy Density | 0.001 g/cm3(cube) |
Measuring Density | 0 g/cm3(cube) to 3 g/cm3(cube) |
Measuring Temperature | 0 to 40 Degree C |
Accuracy Temperature | 0.2 Degree Celsius |
· Quality checks in the field, e. g. on wine and wine must (Brix, KMW, Oechsle, Baume)
· Checks for wort and apparent extract in beer (Plato)
· Fermentation graph for each tank directly on the screen
· One device replaces all glass hydrometers in the workplace
Perfect traceability of density and concentration resultsProduct Details:
Usage/Application | Laboratory |
Brand | Anton Paar Austria |
Measuring systems | Cone-Plate: CP40, CP41, CP42, CP51, CP52 |
Temperature range | 0 Degree C to 100 Degree C |
Model | PTD 100 Cone-Plate |
Accuracy | +-1.0 % of full-scale range |
Repeatability | +-0.2 % |
For small sample volumes from 0.5 mL to 2 mL
Upgrades ViscoQC 100 and 300 to a cone-plate viscometer
Two in one: Cone-plate and Peltier temperature device combined
Automated gap setting process
Magnetic coupling, Toolmaster™ feature, and temperature probe as standard
Key features:Upgrade to a cone-plate viscometer anytimeProduct Details:
Brand | HAL Technology |
Usage/Application | Laboratory |
Model | HAL-HPC600 |
Warranty | 1 Year |
Storage | Up to 6000 internal data memory |
Product Details:
Set of weights | 50 g up tp 425 g |
Test stripsc | 15 mm width, length < 250 mm |
Brand | Brugger Germany |
Dimensions | 40 x 18 x 25 cm |
Weight | 4,5 kg |
Storage temperature | 0 DegreeC - 50 DegreeC |
Working temperature | 15 DegreeC - 35 DegreeC |
Model Name | Hot Tack Attachment |
This HSG accessory enables you to quickly determine the strength of sealing seams immediately after heat sealing. This user-friendly accessory can be quickly attached together with special sealing jaws. To optimise the speed of the process, you may wish to produce exact samples with our Strip Cutter (STR).
Immediately after sealing the two sealed samples are dropped on a wedge by means of a floating weight (50 to 425 g) to split the hot seal seam. The length of the split seam depends on the Hot Tack properties of the material.
After completion of the Hot Tack test you simply need to measure the length of the remaining (non-split) sealing seam and document the result. An optional Microsoft® Access based Software enables you to document your test results with a click of the mouse. The whole procedure – from testing to documentation – is only a matter of a few minutes.
This test enables you to determine the exact Hot Tack properties of various materials with a minimum of effort. This accessory is indispensable for efficient QA procedures during production as well as for the determination of the appropriate sealing parameters during development.
Test method | Qualtitative determination of the Hot Tack properties by dropping the freshly sealed seam on a split mandrel using a falling weight |
Set of weights | 50 g up tp 425 g |
Sealing Jaws | 40 mm x 20 mm, teflonised |
Test strips | 15 mm width, length < 250 mm |
Dimensions | 40 x 18 x 25 cm |
Weight | 4,5 kg |
Storage temperature | 0 °C – 50 °C |
Working temperature | 15 °C – 35 °C |
Relative humidity | max. 80 %, non-condensing |
Hot Tack connection | via internal HSG treadle |
Standard | DIN 55571-1, Hot-Tack – Part 1: Position measuring devices |
Product Details:
Brand | RK Printcoat UK |
Model Number/ Name | K Lox Proofer |
Application | Laboratory |
The simplest method of applying flexo inks and other fluid coatings onto any substrate to produce accurate and repeatable proofs that closely resemble conventional flexo printing. The K Lox Proofer is an essential tool for ink makers and printers alike. Ideal for quality control and presentation samples, R&D and computer colour matching data.
Product Details:
Usage/Application | Laboratory |
I Deal In | New Only |
Brand | RK Printcoat UK |
Printable speed | 100 m/min |
Model Number/Name | GP100 |
High quality proofs using gravure inks of press viscosity are produced instantly using the new GP100. Featuring a microprocessor controlled servo drive and pneumatic operation, electronically engraved printing plates and variable printing speeds of 1 to 100m/min, this is an essential tool for all those involved in the manufacturing or use of liquid inks. Ideal for R&D and computer colour matching data, quality control and presentation samples, the GP100 is very easy to clean.
Product Details:
Brand | Thermo Fisher Scientific USA |
Usage/Application | Laboratory |
Model Name/Number | General Protocol Ovens |
Warranty | 1 Year |
Operating temperatures | 50 DegreeC to 250 DegreeC |
Perform routine applications simply and safely with Thermo Scientific™ Heratherm™ General Protocol Ovens. These ovens provide an ideal heating and drying solution for research, clinical or industrial needs.
Product Details:
Brand | Gel Instrumente AG |
Temperature Range | 0 - 400 Degree C |
Accuracy | +- 1,5 DegreeC including cold-junction compensation |
Connector | Mini connector typ K thermocouples, EN 60 584 |
Sensor | Thermocouple type K (Ni-CrNi), EN 60 584 |
Model | PTC-3 |
Warranty | 1 Year |
3 Channel System: Control Unit with Temperature Measurement, incl. Software Software
The Gelnorm®– Geltimer PTC-3 evaluates all factors which influence the gel time of reaction resins such as type and quantity of hardener, accelerator, inhibitor, filler, pigments, as well as temperature and moisture. The instrument is extremely easy to operate and normally needs no maintenance.
The principle of measurement of Gelnorm®– Geltimer is simple: A stamper made of aluminium or stainless steel performs an up-down cycle in a test tube filled with resin. When the point of gelation is reached, the test tube is pulled up by the stamper. This stops the clock which was started at the beginning of the experiment and the gel time can be read of.
With the probe temperature system the exothermic reaction can be measured. With the optional temperature controller PTT-3 and electric heating Block GT the sample mixture can be heated up and controlled.
Temperature control for the electrical heating block GT
Actual value (Pt100) | Range: 0,0 °C … 250,0 °C, adjustable and calibrated |
Accuracy | ± 0,3% of full scale ± 1 digit |
Set value | Range: 0,0 °C … 200,0 °C (on request 250,0 °C) |
Resolution | 0,1 K |
Load output | Power max. – resistive load: maximum 600 W |
Temperature measurement for the sample
Sensor | Thermocouple type K (Ni-CrNi), EN 60 584 |
Connector | Mini connector typ K thermocouples, EN 60 584 |
Range | 0,0 °C … 400,0 °C |
Accuracy | ± 1,5°C including cold-junction compensation |
Time
Display | LCD, 12mm |
Start button | with status indicator |
Stop | optical switch |
Range | up to 99HH: 59MM: 59SS |
Accuracy | ± 1 second / 2 hours |
Product Details:
Model Name/Number | coatmaster Inline |
Brand | Coatmaster |
Usage/Application | Laboratory |
Relative standard deviation | <1% |
Substrate | Metal, Plastic |
Warranty | 1 Year |
Smallest measuring point | 1 mm |
Product Details:
Brand | GBPI |
Model | GBK-D1 |
Operating Temperature | Room Temperature to 210 Degree Celsius |
Displacement sensor accuracy | +-0.07 mm |
temperature fluctuation | +- 0.2 Degree Celsius |
Product Details:
Brand | CHN Spec |
Model Name/Number | CRX-50,CRX-51,CRX-52 |
Warranty | 1 Year |
Product Details:
Usage/Application | Laboratory |
Model Number/ Name | Flexiproof 100/UV |
Brand | RK Printcoat UK |
Product Details:
Model Name/Number | Gas Permeability Tester GDP-C |
Brand | Brugger Germany |
I Deal In | New Only |
Measuring range | 0 hPa to 1100 hPa |
Dimensions | 50 x 31 x 74 cm |
Test gas | All non-corrosive and non-flamable gases |
Sample temperature range | -20 DegreeC to 80 DegreeC (with external thermostat) |
Storage temperature | 0 DegreeC - 50 DegreeC |
Working temperature | 20 DegreeC - 26 DegreeC (to be constant during operation when testing films with a low GTR) |
Test method | Quantitative determination of the gas permeability of film materials using differential pressure (manometric method) |
Test gas | All non-corrosive and non-flamable gases |
Recommended gas flow | 60 to 100 cm³/min |
Measuring Range | 0.5 cm³/(m²×d×bar) to 30,000 cm³/(m²×d×bar) |
Resolution | 0.1 cm³/(m²×d×bar) |
Main pressure sensor | piezoresistive element, temperature stabilised |
Measuring range | 0 hPa to 1100 hPa |
Tolerance (absolut) | < 0.3 % of the final pressure (1000 hPa) |
Resolution | 0.01 hPa (display) , 21 Bit (internal) |
Data storage | up to 4096 test values (with dynamic time interval selection) |
Pressure absorption gauge | piezoresistive element (0 hPa to 2000 hPa) |
Tolerance | < 1% of the final pressure (1000 hPa) |
Resolution (display) | 0.1 hPa |
Data storage | up to 512 test values (width dynamic time interval selection) |
Sample temperature range | -20 °C to 80°C (with external thermostat) |
Tolerance ( temperature sensors) | +/- 1.5 °C |
Resolution of the temperature display | 0.1 °C |
Data storage | up to 512 test values (with dynamic time interval selection) |
PC interface | serial interface RS232, 115.200 Baud |
Dimensions | 50 x 31 x 74 cm |
Weight | 20 kg |
Storage temperature | 0 °C – 50 °C |
Working temperature | 20 °C – 26 °C (to be constant during operation when testing films with a low GTR) |
Relative humidity | max. 80 %, non-condensing |
Electrical connection GDPC | 230 V / 50 – 60 Hz, power consumption ca. 50 W, approx. |
Electrical connection PC | 230 V / 50 – 60 Hz, power consumption ca. 50 W, approx. |
Electrical connection monitor | 230 V / 50 – 60 Hz, power consumption ca. 150 W, approx. |
Electrical connection(Thermostat) | 230 V / 50 – 60 Hz, power consumption ca. 2300 W, approx. |
Standard | ISO 15105-1 / ASTM D1434-82(2015) procedure M |
Product Details:
Brand | Lovibond UK |
Warranty | 1 Year |
Model | AF650 |
Applicable Standard | ASTM D1500 ASTM D6045 ISO 2049 |
Color Type | Transparent |
Portability | Benchtop |
Product Details:
Model Name/Number | Battery Testing Instrument |
Brand | DGBELL |
Application | Laboratory |
Many electronic products are around our daily life nowadays, smartphones, tablet, wearable devices, laptops, home robots, etc. The rechargeable battery, mainly Lithium-ion battery are widely adopted in such products. There is a greater demand for battery safety testing from both battery and product manufacturers. They should make sure the battery is qualified before delivering it to customers. As a lithium battery test chamber supplier, DGBELL dedicated to the R & D of battery safety tests in China with many technical patents. In this 10 years experiment of researching and manufacturing, we keep developing new equipment and improving the battery test system from cooperating with thousands of customers. DGBELL dedicates to provide a reliable and comprehensive solution for lithium battery test chambers, matching the standard IEC 62133, UN 38.3, and UL 1642. Including mechanical, electrical and temperature environmental test chambers.
Product Details:
Cured powder / dried paints | 1 - 1000 um |
Brand | Coatmaster |
Model | Handheld coatmaster Flex |
Powder coatings before curing | 1 - 400 um |
Measuring time | from 20 ms |
Wet paints before drying | 1 - 400 um |
This handheld is the most innovative one in terms of contactless coating thickness measurement.
Would you like to measure the coating thickness early in the process in order to save material and avoid coating mistakes? Then the coatmaster Flex is the right measurement device for you.
Optimize your process and get your coatmaster Flex now.
Convince yourself of the efficiency and save up to 6’000 Euro per month of coating material per production line. Reduce rejects and increase production quality.
Product Details:
Model Name/Number | HDT - VICAT |
Usage/Application | Laboratory |
Brand | Noselab ats |
I Deal In | New Only |
Operating temperature | from ambient to 300 Degree C. |
Temperature uniformity | +- 0.2 Degree C |
Product Details:
Thermal stability | +-0.2 DegreeC in the test area |
Operating temperature | 80 - 400 Degree C |
Accuracy | 0.1 Degree C |
Brand | Noslab ats |
Model | A-MeP |
Product Details:
Model Name/Number | N530 |
Usage/Application | Laboratory |
Brand | GBPI |
I Deal In | New Only |
Product Details:
I Deal In | New Only |
Brand | RK Printcoat UK |
Model | Paste Ink Proofer |
Application | Laboratory |
High quality proofs using gravure inks of press viscosity are produced instantly using the new GP100. Featuring a microprocessor controlled servo drive and pneumatic operation, electronically engraved printing plates and variable printing speeds of 1 to 100m/min, this is an essential tool for all those involved in the manufacturing or use of liquid inks. Ideal for R&D and computer colour matching data, quality control and presentation samples, the GP100 is very easy to clean.
Product Details:
Brand | W.S. Tyler |
Model Number/Name | Test Sieves |
Product Details:
Brand | Metrohm Swizz |
Model Name/Number | M101 |
Number of current ranges remarks | 10 nA to 10 mA |
Potential and current accuracy | V: +- 0.2% +- 2 mV and i: +- 0.2% +- 0.2% of current range |
Warranty | 1 Year |
The Multi Autolab/M101 is a multi channel potentiostat/galvanostat based on the compact Autolab PGSTAT101. It consist of a Multi Autolab Cabinet which can be fitted with up to 12 M101 modules. Each M101 is a completely independent potentiostat/galvanostat, allowing you to perform different measurements on each channel at the same time.
The Multi Autolab can be controlled from up to three different computers simultaneously, allowing to share the available channels among different users.
The Multi Autolab instruments can be complemented by a selection of optional modules. Each M101 module can be coupled to one optional module in the instrument. The maximum number of optional modules is 6. Optional modules or additional M101 modules can be installed at any time.
Product Details:
Brand | Metrohm Swizz |
Model Number/ Name | 925 / Eco IC |
iColumn technology | 1 separation column |
PC connection | USB |
Warranty | 1 Year |
Discover Eco IC, an ion chromatography system that focuses on the essentials while not compromising on quality, robustness, and reliability. Whether you need to perform routine water analysis or you’re looking for an instrument for higher education, Eco IC comes with all the components you need. In addition, you can also save time and reduce work by getting an automated system.
Product Details:
Brand | Thermo Fisher |
Warranty | 1 Year |
Model | PC-FTS |
Temperature Range | 13 DegreeC to 200 DegreeC |
The Horizon Fogging Test System fulfills the DIN, ISO, and SAE standards for fog testing. Available with a choice of controllers, a range of features and a robust pump providing temperature accuracy of ±0.5°C throughout the entire bath ensuring consistent, repeatable results.
PC-FTS
Includes:
Controller, bath, 6 foot power cord
Product Details:
Brand | Thermo Fisher Scientific USA |
Model Name/Number | Recirculating Chillers |
Warranty | 1 Year |
Pump Capacity | Up to 15gpm @ 34 psig (56.8 lpm @ 2.3 bar) (50Hz),Up to 15gpm @ 57 psig (56.8 lpm @ 3.9 bar) (6hz) |
Temparature Range | -5 to 90 Deg C |
Optimized for the most demanding applications, Thermo Scientific™ ThermoFlex Recirculating Chillers are reliable, easy-to-use and easy-to-maintain. The ThermoFlex platform was developed with customer input from concept to design. This high-performance chiller platform, with cooling capacity up to 24,000 watts (81,948 btu/hr), is configurable to meet application demands.
Superior Performance:
Configurable Design:
Recommended for:
Product Details:
Model Name/Number | DS2500 |
Brand | Metrohm Swizz |
Warranty | 1 Year |
Samples | Liquid/Solid |
The DS2500 Analyzers are compact near-infrared (NIR) spectrometers for use in the lab as well as in production. These instruments combine efficiency and intuitive operation with flexibility and robustness.
Product Details:
Warranty | 1 Year |
Model Name | Purelab Quest |
Brand | Metrohm Swizz |
When you need unmatched value, proven reliability and uninterrupted discovery, PURELAB Quest provides the perfect solution. Consistently delivering three types of laboratory water, the PURELAB Quest supports every application in your lab.
With Purelab Quest get 3 types of water from one system. Space saving design means a more efficient lab and team.
Provides a reliable supply of:
Product Details:
Brand | Lovibond UK |
Model | Comparator System 2000 |
Warranty | 1 Year |
The Comparator 2000+ is an easy-to-use, entry level colour measurement system that compares the colour of the sample directly against the colour of glass in a disc. All you need to do is rotate the disc to get the closest result to the scale.
Product Details:
Brand | Lovibond UK |
Model | Comparator Colour Discs |
Warranty | 1 Year |
· Easy to use, visual assessment of colour – simply rotate disc for colour match
· Glass fade-free standards for longevity of use
· Optional lighting units for guaranteed lighting conditions 24 hours a day
· Optional Nessleriser systems for longer path lengths
Product Details:
Brand | Thermo Fisher USA |
Temperature Range | +5 to +70 Deg C |
Warranty | 1 Year |
Product Details:
Model Number/ Name | PENDULUM SKID TESTER |
Brand | Mastrad |
The Pendulum Skid Tester is the high quality skid resistance testing equipment. Originally designed in the 1940s in the US, the instrument was further developed in the 1960s at the UK Transport Research Laboratory for the testing of road surfaces. The pendulum measures the frictional resistance between a rubber slider mounted on the end of a pendulum arm and the test surface. This provides highway engineers with a routine method of checking the resistance of wet and dry surfaces to slipping and skidding, both in the lab and on site. It is based on the Izod principle: a pendulum rotates about a spindle attached to a vertical pillar. At the end of the tubular arm a head of known mass is fitted with a rubber slider. The pendulum is released from a horizontal position so that it strikes the sample surface with a constant velocity. The distance travelled by the head after striking the sample is determined by the friction of the sample surface. A reading of Skid Resistance is obtained.
Key FeaturesProduct Details:
Brand | Noselab ats |
Model | DENSITY GRADIENT |
Application/Usage | Laboratory |
Warranty | 1 Year |
Raw material characterisation
It allows the determination of the density of solid materials at a temperature of 23°C .
In a measuring range between 0.84 and 2.6 g / cm³ based on the use of spheres with a known density.
Small glass spheres (marker float) of known density are lowered into the column and stop when their density coincides with the density of the solution in which they are immersed. To determine the density of a sample it is necessary to immerse it in the same column and wait until it has stopped, having reached the equilibrium between its density and that of the solution.
Product Details:
Model Name/Number | Y310 |
Brand | GBPI |
GBPI Oxygen Permeabililty Tester Y310 Features:
1. Coulometric sensor method: the main national method, the general international method.
2. Automatic temperature monitor, program controlled temperature increase and decrease, precision: 0.1°C.
3. Humidity control: dual gas flow method, stable, precision 1%RH; gas flow auto compensation.
4. Y310 Oxygen Permeation Analyzer test range can extend to 260000 cm3/(m2·24h) by installing extra fittings.
5. By installing extra fittings, can extend function to test finished packaging product, such as plastic bowl, bottle, bag and
so on.
6. With quick test function.
7. Can extend to maximum 12 chambers.
8. Standard gas calibration and standard film calibration.
9. Three chambers can do independent test and independent report for two different samples; support cross testing of two chambers.
10. Built-in computer, can work without external computer.
11. Touch screen.
12. Auto judgment and auto stop.
13. Sensor auto protection.
14. Real time display and auto record of curves and data of transmission rate, oxygen density, humidity and temperature.
15. Will not change the properties of test sample during testing; support continuous testing in certain temperature and humidity.