Product Details:
Brand | Rhopoint UK |
Model Name/Number | Shade Duo + Shade |
Power Supply | Rechargeable lithium-ion battery, 17+ hours operation 20,000+, readings per charge |
Memory | 8 MB = 999 readings User definable alphanumeric batching |
Operating Temperature | 15 Degree C - 40 Degree C |
Standards | ASTM E97, ASTM D4214, ASTM D2805, ASTM D589, BS 3900-D4, BS 3900-D7, DIN 6125, ISO 2814, ISO 6504 |
Performance | Resolution 0.1, Repeatability 0.2%, Reproducibility 0.5% |
Warranty | 1 Year |
A versatile solution for reflectometry measurement
The Novo-Shade Duo+ is a portable 45/0° reflectometer that can be used to assess either the shade of a surface (a simple indication of colour based on lightness/darkness) or calculate the opacity of a coating, plastic film or paper sample. By measuring using 45/0°, the Novo- Shade Duo+ measures the colour of a surface and not the specular reflectance (gloss).
· Measure opacity (hiding power)
· Measures shade on grayscale
· Suitable for measuring coatings or plastic films
Shade mode
To measure the shade of a coating simply place the instrument on the surface of the sample to be measured and press the centre button. The value is displayed on the screen. The shade measurement is based on a greyscale value where black has a value of zero and white is the value of the calibration standard included with the instrument.
Opacity modeTo measure the opacity of a coating, it must be drawn down on a Leneta-type opacity chart at the required film weight and allowed to fully dry. To measure the opacity of plastic film, paper, textile or any other semi-opaque material, the sample to be measured should be placed over a black and white test bed, a Leneta-type chart is also suggested.
Cleanliness modeTo measure cleanliness, clear tape is used to collect debris from the surface under test. This is then stuck to any suitable white substrate along with a sample of tape that is perfectly clean.
FeaturesThe instrument is controlled by pressing the relevant touch sensitive buttons. Functionality is dependent on which operating mode the instrument is in.
Pass/FailThe Pass/Fail setup screen is used to enable/disable on-screen pass/fail indication and set min/max tolerancing for easy identification and reporting of non-confomances.
Power20,000+ readings per charge. The instrument is rechargeable via USB/PC or mains.
Software-free Rapid Data Transfer
USB connection to a computer instantly recognises the device as a drive location which facilitates the quick transfer of files using Windows File Explorer or similar software.
Operation